GEOGRID
VYKING.NET WEBSITE
(download specs
and Technical Info
click here)

Customer/Project Information

1) Customer Name ________________________________________Phone ____________________Fax ____________________

Address __________________________________________City ______________________State ____________________

o Wall Contractor o DIY Homeowner o Arch/Engr o Other __________________________________________

2) Project Name ______________________________________________________________________________________________

Address __________________________________________City ______________________State ____________________

Type: o Residential o Commercial o Municipal o Other____________________________________________

3) Dealer ____________________________________________________________________________________________________

4) Engineer/Designer________________________________________Phone ____________________Fax ____________________

5) Stamped Engineering Needed? o Yes o No

Wall Information

1) Retaining Wall Unit: ________________________________________

2) Exposed Height of Wall: Feet _____________ Courses_____________

3) Total Height of Wall: Feet _____________ Courses_____________

Is your retaining wall project multi-tiered or terraced? o Yes o No

Soils Information - Is a soils report available? o Yes o No

1) Indicate Type of Soil Soil Types: (a, b or c)

Reinforced Fill __________________________ a: Granular- sand & gravel (gritty)

Retained Soil __________________________ b: Clay – plastic silts & clay (slick)

Foundation Soil __________________________ c: Organic – loam & peat

2) Indicate Type of Base/Leveling Pad

o Sand o Processed Gravel/Crusher Run o Gap-graded Crushed Stone

o Other (describe)________________________________________________

Slope & Surcharge:

1) Indicate Type of Surcharge or Load at TOP of Wall:

o Lawn or grassy area o Auto parking/Light traffic o Truck parking/Highway traffic

2) Slope at BOTTOM/FRONT of Wall - see diagram:

a) Is there a slope in front of the wall? o No o Yes: Angle of slope (ex. 2 horizontal:1 vertical) Horizontal_______Vertical_______

3) Slope at TOP of Wall - see diagram:

a) Is there a slope at top of the wall? o No o Yes: Angle of slope (ex. 2 horizontal:1 vertical) Horizontal_______Vertical_______

b) Is the slope height greater than 2 times the height of the wall? o Yes o No - indicate the slope height (ft)________________

Preliminary Design Request Form Date__________________

By submitting this form I acknowledge that the information to be provided is not intended to replace a site specific design performed

by a professional engineer and the final determination of the suitability of the information is the user’s responsibility.

Information Supplied by (please print): ______________________________________________________________________________________

Signature (required) ______________________________________________________________________________________________________

X Foundation Soil (under leveling pad)

t Reinforced Soil

0 Retained Soil

~ Base/Leveling Pad

4) Is internal or external water involved? o YES o NO

Return copies of preliminary designs by: o Fax:_________________________ o Email:_____________________________

Name: ______________________________________________Phone: ______________________________________________

Address: ______________________________________________City: __________________State: ______Zip: ______________

 

Engineered Walls:

 

Gather Data to answer the basic questions asked when designing an engineered

wall by filling out the SRW Preliminary Design Request Form

Fax, email or bring “The request form” to Landis Block and it will be

submitted for a “Preliminary “Pre Bid” design drawing” showing

geogrid placement, stones, caps and adhesive needed for the job. There

is no charge for this service. If you need a stamped print of this work it

can be arranged for an up charge per sq ft.

Directions and Installation Procedures are available at VYKING.NET

Vyking Walls over 3’ in height may require the services of a licensed engineer

trained in Segmented Retaining Walls (SRW).

Obtain a copy of “Segmental Retaining Wall Installation Guide” published

by the National Concrete Masonry Association and become familiar

with the best practices for installation of this type of wall system.

There are Standard Geogrid Placement tables available at Vyking.net for

certain walls that meet the criteria discussed.

Consult the local municipal authority for applicable building codes governing

SRW Walls.

Vyking Technical Hotline 573-230-4974 (7 DAYS)

CALL: 215-723-5506

FAX: 215-723-5500

WEB: http://landisbc.com

 

Next Geogrid Page

 If there are three things every builder should understand about SRWs, they are reinforcement, compaction and drainage. Georgrid soil reinforcement is the re-bar of SRWs. Many building codes require permitting for walls taller than 4 feet, which typically results in a design submittal of some form. Furthermore, depending on the size and weight of the SRW unit, geogrid soil reinforcement might be necessary to ensure stability of the entire structure.